Never connect Power Supplies in parallel. This leads to congestion and failure of the Power Supply. Exception: special Power Supplies with function "parallel".
- Series connection possible:
For example 2 Power Supplies 12V 100W give in the series circuit 24 V, while the output is increased by about 90% and amounts to 180-190 W. This method is applicable if the use of larger Power Supplies, lack of space is not possible.
- Not allowed is the use of Power Supplies at ambient Temperatures above +60 ° C or below -25 ° C, or in direct Sunlight.
- Typical Errors which lead to failure and loss of Warranty:
- Installation in a closed Room without ventilation
- Installation of the Power Suplie side by side or heat generating surfaces
- Operation of the Power Supply without Protection against precipitation (snow, rain)
- Inattention while connecting, supply of 230 V at the output of the power supply.
|

|
|
|